Protective airtight doors
Technical sheet Doors · 100 kPa
- 02 Rated pressure
- 03 Clear passage width
- 04 Clear passage height
- 05 Door leaf thickness
- 01MassΔ differs180 kg
- 02Rated pressureΔ differs100 kPa
- 03Clear passage width800 mm
- 04Clear passage height1,800 mm
- 05Door leaf thicknessΔ differs60 mm
01MassΔ differs
180 kg
02Rated pressureΔ differs
100 kPa
03Clear passage width
800 mm
04Clear passage height
1,800 mm
05Door leaf thicknessΔ differs
60 mm
rev. r2
Δ Δ marks values that differ between versions.
- Name
- Doors · 100 kPa
- Rev.
- r2
- Status
- Sketch
- Note
- Illustrative drawing · dimensions in mm
Technical sheet Doors · 400 kPa
- 02 Rated pressure
- 03 Clear passage width
- 04 Clear passage height
- 05 Door leaf thickness
- 01MassΔ differs240 kg
- 02Rated pressureΔ differs400 kPa
- 03Clear passage width800 mm
- 04Clear passage height1,800 mm
- 05Door leaf thicknessΔ differs90 mm
01MassΔ differs
240 kg
02Rated pressureΔ differs
400 kPa
03Clear passage width
800 mm
04Clear passage height
1,800 mm
05Door leaf thicknessΔ differs
90 mm
rev. r3
Δ Δ marks values that differ between versions.
- Name
- Doors · 400 kPa
- Rev.
- r3
- Status
- Sketch
- Note
- Illustrative drawing · dimensions in mm
- Base price
- from €2,100 net
- Delivery
- Our team will agree on delivery, unloading and installation after receiving your inquiry.
- Payment
- outside the site, as quoted
Airtight protective doors in two versions: 100 kPa and 400 kPa. They are secured in the wall opening with anchors.
- Specifications
- Verified properties
- Kit and equipment
- Installation and access
- Documents
- Terms
- Request a quote
- Questions
Verified properties
Manufacturer statement · Material · The door leaf is made from steel sheet of a verified grade.
Limits · The certificate covers the material only. It does not verify the resistance of the door.
Evidence · Inspection certificate for door leaf steel sheet PL
Certificate · Issued by Huta Przykładowa · No. 3.1-2026-0091 · Date
Test specimen · Steel sheet used for the door leaf
Document entry
In-house testing · Sample description of the variant 400 test.
Limits · Test scope to be confirmed.
Evidence · Variant 400 test report · In preparation
Test report
Scope · Variant 400 · rev. r3
Document entryIndependent test report · The variant 400 door leaf passed a 400 kPa overpressure test.
Limits · Variant 400, rev. r3 only. Installation in the opening was outside the test scope.
Evidence · Independent 400 kPa door test report
Test report · Issued by Laboratorium Przykładowe · No. LP-2026-014 · Date
Scope · Variant 400 · rev. r3
Test specimen · 400 kPa door leaf, rev. r3, test specimen
Document entryManufacturer statement · Material · The door leaf is made from steel sheet of a verified grade.
Limits · The certificate covers the material only. It does not verify the resistance of the door.
Evidence · Inspection certificate for door leaf steel sheet PL
Certificate · Issued by Huta Przykładowa · No. 3.1-2026-0091 · Date
Test specimen · Steel sheet used for the door leaf
Document entry
Kit and equipment
Included
- Steel door frame with anchorsΔ differs
- Door leaf with perimeter seal
- Two adjustable hinges
- 4 wedge latches with leversΔ differs
- Interior handle
- Installation instructions
Δ marks items that depend on the version.
Included
- Reinforced door frame with anchorsΔ differs
- Door leaf with perimeter seal
- Two adjustable hinges
- 6 wedge latches with leversΔ differs
- Interior handle
- Installation instructions
Δ marks items that depend on the version.
Installation and access
- Opening width
- 900 mm
- Opening height
- 1,900 mm
- Opening width
- 900 mm
- Opening height
- 1,900 mm
Installation
- Measure the opening
Dimensions and wall type from drawings or an on-site check.
- Fit the frame
Anchor and grout as specified in the installation instructions.
- Adjust and inspect
Set the hinges and latches and check the seal.
Documents
- Inspection certificate for door leaf steel sheetDocument availableDownload PDF PL
Certificate · Material · Issued by Huta Przykładowa · No. 3.1-2026-0091 · Date
Test specimen · Steel sheet used for the door leaf
Confirms · Grade and properties of the steel sheet
Limits · Covers the material only. The complete door is outside its scope
Valid until
- Door instructionsIn preparation
Instructions
Scope · rev. r1 · previous revision
- Technical sheet — supplied with the quoteRequest the technical sheet
- Variant 400 test reportIn preparation
Test report
Scope · Variant 400 · rev. r3
- Independent 400 kPa door test reportDocument availableDownload PDF
Test report · Issued by Laboratorium Przykładowe · No. LP-2026-014 · Date
Scope · Variant 400 · rev. r3
Test specimen · 400 kPa door leaf, rev. r3, test specimen
Confirms · The door leaf withstood 400 kPa overpressure under the test conditions
Limits · Excludes variant 100 and installation in the opening
- Inspection certificate for door leaf steel sheetDocument availableDownload PDF PL
Certificate · Material · Issued by Huta Przykładowa · No. 3.1-2026-0091 · Date
Test specimen · Steel sheet used for the door leaf
Confirms · Grade and properties of the steel sheet
Limits · Covers the material only. The complete door is outside its scope
Valid until
- Door instructionsIn preparation
Instructions
Scope · rev. r1 · previous revision
- Technical sheet — supplied with the quoteRequest the technical sheet
Terms
from €2,100 net
Our team will agree on delivery, unloading and installation after receiving your inquiry.
Tax basis · net
- Model (base configuration)
- from €2,100 net
- Optional equipment
- quoted separately
- Delivery
- agreed after we receive your inquiry
- Unloading and installation
- agreed after we receive your inquiry
- Site preparation
- agreed after we receive your inquiry
Steps to a quote
- Inquiry
- Site check
- Quote
Ask about the door
Tell us about your installation site and the equipment you need.
Questions
Which version should I choose?
It depends on the room design requirements. Describe them in your inquiry.
Is there a test report for the door?
Check the documents and test scope for the selected version.
Do you install the doors?
The quote sets out the scope of installation.